Mastering Trip Matrix of 132kV Substation
Learn from Professionals, Electrical Power Engineering
Description
Course title:
Mastering Trip Matrix of 132kV Substation
Course Description:
Dear All,
This course covers the complete tripping scheme of 132kV substation, I have started the course by explaining the single line diagram of substation. Later explained the philosophy of protection system, how relays, circuit breaker & battery banks works in a substation. I have explained the topics from very basic level so that anyone with limited knowledge can also learn from this training.
This training consists of 15 lectures and 1 :26 hours duration of video
I have utilized my 18plus years of field experience & try to deliver my best.
After completing this training, you will be able to understand the trip matrix, basic protection relay functionality of substation.
The following topics are covered in this training.
1. Single Line Diagram of 132kV substation
2. Protection philosophy
3. Trip coil & closing coil functionality
4. Requirement of two trip coils in system
5. Redundant battery bank, trip circuits & chargers
6. Fast tripping relays, why tripping relays are used
7. Lockout relays with ANSI code 86
8. Tripping relays with ANSI code 94
9. What is close block and when it is used
10. Where to use 86 and 94 relays
11. Busbar protection basics
12. Breaker Failure scheme basics
13. CBF stage 1 & 2 scheme
14. CBF direct transfer trip in case of stage 2
15. CBF adjacent breaker tripping
16. Trip coil save feature
17. Direct tripping from relay contacts and when to use it.
18. Advantages and disadvantages of tripping from Main relay contacts
19. Reviewed trip circuit schematics from detail drawing
20. Lockout relay schematics
21. Differential, distance, communication scheme, synch check, AR basic theory
22. Switch on to fault function
23. Transformer mechanical and electrical trip basics
24. Relay and metering SLD basics of line and transformer feeder
25. Trip matrix of line and transformer protection
Material to download:
· Substation Single Line Diagram
· 132kV line feeder trip matrix
· 132kV transformer feeder trip matrix
· Detail transformer protection panel schematics
· Detail line protection panel schematics
· Presentation
Wish you the best of luck.
What You Will Learn!
- Single Line Diagram of 132kV substation
- Protection philosophy
- Trip coil & closing coil functionality
- Requirement of two trip coils in system
- Redundant battery bank, trip circuits & chargers
- Fast tripping relays, why tripping relays are used
- Lockout relays with ANSI code 86
- Tripping relays with ANSI code 94
- What is close block and when it is used
- 1Where to use 86 and 94 relays
- Busbar protection basics
- Breaker Failure scheme basics
- CBF stage 1 & 2 scheme
- CBF direct transfer trip in case of stage 2
- CBF adjacent breaker tripping
- Trip coil save feature
- Direct tripping from relay contacts and when to use it.
- Advantages and disadvantages of tripping from Main relay contacts
- Reviewed trip circuit schematics from detail drawing
- Lockout relay schematics
- Differential, distance, communication scheme, synch check, AR basic theory
- Switch on to fault function
- Transformer mechanical and electrical trip basics
- Relay and metering SLD basics of line and transformer feeder
- Trip matrix of line and transformer protection
Who Should Attend!
- Students, technicians, engineers