Testing Commissioning 115 KV GIS
Reading Scheme OF GIS Drawing , Make Interface with Protection And Control Scheme
Description
Dear fellows,
This is the most comprehensive online training of gas insulated substation . Here you will learn all thing about GIS.
Gas insulated substations are the most common type of substation that you will find on the electrical network, due to their effectiveness and simplicity.
This course will give you an appreciation of how to design,commissioning this type of substation and introduce you to all of the equipment's that you will find in a typical gas insulated substation.
we will go through the following topics
Wire Specification And Ferrouling System OF GIS Bays
SF6 GAS Scheme Diagram For All GIS Compartment
The Distribution OF DC Power Supply
Close Circuit Breaker From SAS Operating System and Emergency
The Different Between Service Position OF Circuit Breaker And Maintenance Position
Modification OF Maintenance Position In LCC Drawing
Synchronization Conditions For Circuit Breaker
The Important OF Trip Circuit Supervision For Circuit Breaker
Philosophy of Trip With Mechanical and Electrical Protection
High Impedance BusBar Protection Theory
The Important OF Using Early Make And Late Break Contact For Bus Disconnector
High Impedance BusBar Protection Zone (Discrimination Zone And Check Zone)
Philosophy of Trip For BusBar Protection
Circuit Breaker Fail Protection Theory
Philosophy of Trip For Circuit Breaker Fail Protection
Philosophy of Interlock To Ensure the Safe Operation OF The Stations
Philosophy of Interlock Between HV circuit Breaker And Earth Disconnector in Low Voltage Side
AC And DC Supervision Alarm
What You Will Learn!
- Wire Specification And Ferrouling System OF GIS Bays
- SF6 GAS Scheme Diagram For All GIS Compartment
- The Distribution OF DC Power Supply
- Close Circuit Breaker From SAS Operating System and Emergency
- The Different Between Service Position OF Circuit Breaker And Maintenance Position
- Modification OF Maintenance Position In LCC Drawing
- Synchronization Conditions For Circuit Breaker
- The Important OF Trip Circuit Supervision For Circuit Breaker
- Philosophy of Trip With Mechanical and Electrical Protection
- High Impedance BusBar Protection Theory
- The Important OF Using Early Make And Late Break Contact For Bus Disconnector
- High Impedance BusBar Protection Zone (Discrimination Zone And Check Zone)
- Philosophy of Trip For BusBar Protection
- Circuit Breaker Fail Protection Theory
- Philosophy of Trip For Circuit Breaker Fail Protection
- Philosophy of Interlock To Ensure the Safe Operation OF The Stations
- Philosophy of Interlock Between HV circuit Breaker And Earth Disconnector in Low Voltage Side
- SF6 Alarm For All GIS Compartment
- AC And DC Supervision Alarm
Who Should Attend!
- Anyone interested in electrical engineering
- Electrical undergraduates
- Electrical graduates
- Workers in the electrical utility industry
- Electricians