Testing Commissioning Protection MiCOM Relays
Commissioning MiCOM Relays ( P142 - P443 - P546 - P643)
Description
Dear fellows,
This is the most comprehensive online training of Testing Commissioning MiCOM Relays . Here you will learn all thing about MiCOM Relays ( P142 - P443 - P546 - P643)
This course will give you an appreciation of how to commissioning this type of Protection Relays
we will go through the following topics :-
Introduction to Micom Protection Relays
How to communicate with Micom relay
How to configure Micom P142 relay
Building Programmable scheme logic ( PSL)
1st example of using Micom P142 as (overcuurent &earth fault) protection function
2nd example of using Micom P142 as high impedance restricted earth fault protection function
3rd example of using Micom P142 as TEE Protection
Introduction to Micom P443 relay
The importance of CT polarity with directional protection function
How change The Polarity of CT By using MiCOM S1 Agile software
1st example of using Micom P443 as (under&over) voltage protection function
The importance of pole Dead with under voltage protection function
2nd example of using Micom P443 as circuit breaker fail CBF protection function
setting of CBF
The action of CBF with Circuit breaker defective
setting of disturbance recorder
Introduction to Micom P546 relay
1st example of using Micom P546 as directional earth fault
DEF carrier send and carrier receive
VT Supervision
2nd example of using Micom P546 as Distance protection function
Power Swing and Fuse Failure Supervision
Trip Philosophy with Zone 1
Trip Philosophy with Zone( 2-3-4)
Distance communication scheme
Switch onto fault trip SOTF
IT Received Trip From Remote End Substation
Introduction to Micom P643 relay
1st example of using Micom P643 as transformer differential protection
2nd example of using Micom P643 as low impedance restricted earth fault
All the examples that were explained are from real practical examples in reality. I wish you success and success in your practical life.
What You Will Learn!
- Introduction to Micom Protection Relays
- How to communicate with Micom relay
- How to configure Micom P142 relay
- Building Programmable scheme logic ( PSL)
- 1st example of using Micom P142 as (overcuurent &earth fault) protection function
- 2nd example of using Micom P142 as high impedance restricted earth fault protection function
- 3rd example of using Micom P142 as TEE Protection
- Introduction to Micom P443 relay
- The importance of CT polarity with directional protection function
- 1st example of using Micom P443 as (under&over) voltage protection function
- The importance of pole Dead with under voltage protection function
- 2nd example of using Micom P443 as circuit breaker fail CBF protection function
- setting of CBF
- The action of CBF with Circuit breaker defective
- setting of disturbance recorder
- Introduction to Micom P546 relay
- 1st example of using Micom P546 as directional earth fault
- DEF carrier send and carrier receive
- VT Supervision
- 2nd example of using Micom P546 as Distance protection function
- Trip Philosophy with Zone 1
- Trip Philosophy with Zone( 2-3-4)
- Distance communication scheme
- Switch onto fault trip SOTF
- IT Received Trip From Remote End Substation
- Introduction to Micom P643 relay
- 1st example of using Micom P643 as transformer differential protection
- 2nd example of using Micom P643 as low impedance restricted earth fault
Who Should Attend!
- Anyone interested in electrical engineering
- Electrical undergraduates
- Electrical graduates
- Workers in the electrical power utility