Testing Commissioning Protection ABB Relays
Commissioning RED 670 ( Line Differential Protection 87L - Distance Protection 21) and REF 615 Overcurrent Relay
Description
Dear fellows,
This is the most comprehensive online training of Testing Commissioning Protection Relays . Here you will learn all thing about RED 670 and REF 615
RED 670 and REF 615 are the most common type of Protection Relays that you will find on the electrical network, due to their effectiveness and simplicity.
This course will give you an appreciation of how to commissioning this type of Protection Relays
we will go through the following topics
Introduction to Protection Relays with Transmission line feeders
The Different Between Protection Schemes with Transmission line feeders
Install PCM Program and REF 615 Connectivity Package
Overcurrent Relay REF 615 Hardware Configuration
How change The Polarity of CT By using PCM Program
REF 615 Application Configuration
REF 615 Measurement Function Blocks
REF 615 Trip Logic Philosophy
Line Differential Distance Relay RED 670
RED 670 Connectivity Package
RED 670 Binary Input and Output
Transmute Current for Remote End Substation
RED 670 Application Configuration
Line Differential Function Block
Line Differential Trip Philosophy
Distance Protection Introduction
Power Swing and Fuse Failure Supervision
Trip Philosophy with Zone 1
Trip Philosophy with Zone( 2-3-4)
IT Received Trip From Remote End Substation
Communication Scheme (under & over ) Reach Scheme and Blocking Scheme
Current Reversal and Weak- End Feed Protection Function
Switch Onto Fault Function Block
working theory of Auto Re-closure Function
SAS Alarm ,Measurement and Disturbance Recorder
What You Will Learn!
- Introduction to Protection Relays with Transmission line feeders
- The Different Between Protection Schemes with Transmission line feeders
- Install PCM Program and REF 615 Connectivity Package
- Overcurrent Relay REF 615 Hardware Configuration
- How change The Polarity of CT By using PCM Program
- REF 615 Application Configuration
- REF 615 Measurement Function Blocks
- REF 615 Trip Logic Philosophy
- Line Differential Distance Relay RED 670
- RED 670 Connectivity Package
- RED 670 Binary Input and Output
- Transmute Current for Remote End Substation
- RED 670 Application Configuration
- Line Differential Function Block
- Line Differential Trip Philosophy
- Distance Protection Introduction
- Power Swing and Fuse Failure Supervision
- Trip Philosophy with Zone 1
- Trip Philosophy with Zone( 2-3-4)
- IT Received Trip From Remote End Substation
- Communication Scheme (under & over ) Reach Scheme and Blocking Scheme
- Current Reversal and Weak- End Feed Protection Function
- Switch Onto Fault Function Block
- Auto Re-closure
- SAS Alarm ,Measurement and Disturbance Recorder
Who Should Attend!
- Anyone interested in electrical engineering
- Electrical undergraduates
- Electrical graduates
- Workers in the electrical power utility